A high pressure magnetic flow meter (mag meter) measures the volume flow of conductive liquids and liquid-solid mixtures in pressurized oilfield lines. Our series covers DN25–DN250 and five nominal pressure classes from 6.3 to 42 MPa, with PTFE, F46 or PFA liners and Hastelloy or other electrodes.
A high pressure electromagnetic flow meter is a magnetic flow meter built for pressurized lines. It works on Faraday’s law of induction: a conductive fluid moving through a magnetic field produces an induced voltage that the transmitter converts into flow. This guide covers pressure classes, liners and electrodes, oilfield uses, installation and FAQs. Specification figures come from our datasheet; other points are marked for confirmation with us.
Why High Pressure Is Hard on a Magnetic Flow Meter
Pressurized oilfield service puts four items under review: negative pressure, the liner, the connection and the electrode. Each one is a question to confirm, not an assumption.
Negative Pressure and Liner Collapse
Our datasheet describes a special lining technology that resists high pressure and negative pressure. It gives no vacuum level, so we quote none. If your line can see vacuum, give the supplier the lowest expected pressure and ask them to confirm the liner suits it. We do not describe a collapse mechanism.
Liner Fatigue Under Pressure Cycling
If your line cycles between high and low pressure, ask the supplier whether cycling affects liner life. We have no lifetime, cycle count or mechanism data, so we state none.
Electrode Wear in Solids-Laden Fluids
Mud and cement slurry carry solids. The datasheet lists a stainless steel coated tungsten carbide electrode, but it does not say which slurries suit it, so that match is unverified. Velocity guidance for abrasive media is in the applications section.
Specifications and the Five Nominal Pressure Classes
Five Nominal Pressure Classes
The datasheet lists five nominal pressures: 6.3, 10, 16, 25 and 42 MPa. These are nominal classes, not a promise for every build. Actual usable pressure may depend on diameter and liner configuration, so confirm it for your duty with us. We do not convert units here. The datasheet includes outline drawings for the 25 MPa class only, in flange and oil-union types. Their dimensions stay in the original drawing (Figure 3).
Table 1. Nominal pressure classes of the high pressure magnetic flow meter series
| Nominal Pressure (MPa) | Outline Drawing in Datasheet |
|---|---|
| 6.3 | No |
| 10 | No |
| 16 | No |
| 25 | Yes (flange and oil-union) |
| 42 | No |

Core Specifications
The stated application is volume flow measurement of conductive liquids and liquid-solid mixtures. Our high pressure electromagnetic flow meter covers DN25–DN250. Accuracy is ±0.5% as standard, with ±0.3% and ±0.2% optional. Medium temperature is -10 to +160 °C and ambient is -25 to +60 °C. Structure is integral or remote. Dielectric conductivity is marked at 20 μS/cm in the datasheet; this is a specification value, so confirm suitability for your medium with us.

High Pressure Type vs Standard Mag Meters
Table 2 lists the fields our datasheet supports. Standard-meter cells stay blank because this guide quotes only the high pressure datasheet.
| Item | Standard Mag Meter | High Pressure Type | Source |
|---|---|---|---|
| Liner | — | PTFE, F46, PFA | DS |
| Electrode | — | SUS316, Hastelloy B, Hastelloy C, Titanium, SS coated tungsten carbide | DS |
| Accuracy | — | ±0.5% standard; ±0.3%, ±0.2% optional | DS |
| Temperature | — | Medium -10 to +160 °C; ambient -25 to +60 °C | DS, D:7 |
| Conductivity | — | 20 μS/cm (specification value) | DS |
Liner and Electrode Selection for High Pressure Service
Liner Options: PTFE, F46, PFA
The datasheet lists three liners: PTFE, F46 and PFA. It gives no performance ratings, so we quote none. Decide by asking about your medium, its temperature and any negative-pressure duty. Send those three facts with your enquiry.
Electrode Options
Five electrode materials are listed: SUS316, Hastelloy B, Hastelloy C, titanium and stainless steel coated tungsten carbide. We make no corrosion or wear claims for any of them. Match the electrode to the medium chemistry, and for slurry, to solids content as well.
How to Read the Matrix
Table 3 is a question matrix, not a compatibility chart. It tells you what to ask, and the final answer is the configuration confirmation from our team.
| Option | Type (Liner/Electrode) | Listed in Datasheet | Question to Ask | Source Tag |
|---|---|---|---|---|
| PTFE | Liner | Yes | Does it suit my medium at operating temperature? | DS |
| F46 | Liner | Yes | Does it suit my medium and negative-pressure duty? | DS |
| PFA | Liner | Yes | Does it suit my medium and temperature limits? | DS |
| SUS316 | Electrode | Yes | Is it compatible with my medium? | DS |
| Hastelloy B | Electrode | Yes | Is my medium compatible with this alloy? | DS |
| Hastelloy C | Electrode | Yes | Is my medium compatible with this alloy? | DS |
| Titanium | Electrode | Yes | Is my medium compatible with titanium? | DS |
| SS coated tungsten carbide | Electrode | Yes | Does it suit my solids content and flow velocity? | DS |
Applications: Drilling Mud, Cement Slurry and Water Injection
The datasheet names the field of use: geology, petroleum exploration and oilfield systems. Media are conductive liquids or liquid-solid two-phase fluids such as mud, cement slurry and high pressure water injection.
Drilling Mud Flow Meter: Solids and Abrasion
A drilling mud flow meter works with solids in the stream. The datasheet lists mud as a liquid-solid two-phase medium and offers a stainless steel coated tungsten carbide electrode. We do not claim that electrode suits every mud; that match is unverified.
Velocity conventions, common engineering practice and not a standard:
- 2–3 m/s at maximum flow
- above 1 ft/s for slurry, to limit settling
- below 3 ft/s for abrasive media
They come from different contexts, so confirm your target with us. For any mud flow meter enquiry, send mud type, solids content, temperature, flow range, line size, pressure class and connection. Ask which liner and electrode options fit that medium.
Cement Slurry Flow Meter Duty
Cement slurry is the second medium the datasheet lists. Two checks matter: solids and conductivity.
Solids: slurry is liquid-solid, so the velocity conventions above may apply. We have no cement density, mix or setting-time data, so we make no claims on them.
Conductivity: the datasheet marks 20 μS/cm for this model. That is a specification value. Actual suitability depends on your slurry, so confirm it with us.
Use the Table 3 question matrix to prepare your questions. Do not assume a liner or electrode from the medium name alone; the matrix shows what to ask. Then send solids content, temperature, pressure and connection details to our sales team.
Water Injection Flow Meter: High Pressure Wells
The datasheet lists high pressure water injection as a target use. A water injection flow meter for this duty has to be checked on four points: working pressure, line size, medium and materials.
Match your project’s working pressure and DN to the five nominal classes in Table 1. A nominal class is not a confirmed usable pressure for every diameter and liner combination, so do not read it that way.
Send us your pressure, line size, medium conditions and connection type. Our team will check the fit against the datasheet options. We show no well depth, injection pressure or field case data. See our electromagnetic flow meter for high-pressure service.
High Pressure Flow Meter Types Compared: Where an Electromagnetic Meter Fits
Meter types include rotameter, positive displacement, Coriolis, differential pressure and electromagnetic designs. This guide covers the electromagnetic type only. We make no pressure ranking between types.
- No moving parts in the flow path
- No moving-part wear, so no wear parts to replace
- Low pressure loss compared with obstructive meter types
These are common traits of electromagnetic designs, as our product catalogue lists for the electromagnetic range.
Table 4. Meter types and the scope of this guide
| Meter Type | Scope of This Guide | Application / Confirmation Point |
|---|---|---|
| Rotameter | Not covered | — |
| Positive displacement | Not covered | — |
| Coriolis | Not covered | — |
| Differential pressure | Not covered | — |
| Electromagnetic | Covered | Conductive liquids and liquid-solid media, e.g. mud, cement slurry, water injection; confirm medium, materials, DN, pressure class |
First check the fluid is conductive, then confirm medium, materials, DN, pressure class and connection with our team.
Installation and Connection: Flanged vs Oil-Union
Flange Type vs Oil-Union Type
The datasheet lists two connection methods: flange type and oil-union type. Both are offered on this series. See our electromagnetic flow meter range for the wider product line.
- Flanged: choose it when your line is built with flange joints. Figure 3 shows the flange-type outline for the 25 MPa class.
- Oil-union: choose it when your line uses union couplings. Ask our team about oil-union details for your pressure class.
Does the connection rating match the pressure class you select? That is a question for the supplier to confirm. We do not state flange ratings here. Send your connection type and rating requirement with the enquiry.

Grounding, Straight Run and Orientation
Grounding and straight run are common industry practice, not our specification. Typical guidance cites 5D upstream and 2D downstream straight pipe, unverified for this series. Electrode axis horizontal is also commonly advised. For grounding, orientation and straight-run details, follow our installation manual. Both integral and remote structures are available.
Commissioning Notes
Confirm commissioning procedures with our team and follow the installation manual supplied for your configuration. Tell us if your line may run part-full or carry gas, so our team can confirm suitability for that duty. Check your medium’s conductivity with us; the datasheet marks 20 μS/cm as a specification value.
High Pressure Selection Checklist
Confirm these five items before you request a quote.
1. Pressure class: choose from 6.3, 10, 16, 25 or 42 MPa. A nominal class is not a confirmed usable pressure for every DN and liner. 2. Diameter: DN25–DN250. 3. Liner: PTFE, F46 or PFA. 4. Electrode: SUS316, Hastelloy B, Hastelloy C, titanium or SS coated tungsten carbide. 5. Connection: flange type or oil-union type.
Two conditions also apply. Medium conductivity: the datasheet marks 20 μS/cm as a specification value. Temperature: medium -10 to +160 °C, ambient -25 to +60 °C. Review our electromagnetic flow meter specifications before you send your enquiry.
High Pressure Magnetic Flow Meter FAQ
What is the pressure limit of a magnetic flow meter?
It depends on diameter, liner and connection. Our series offers five nominal classes, 6.3 to 42 MPa. Confirm actual usable pressure for your duty with us. We give no unit conversions here.
Can a magnetic flow meter handle negative pressure?
Our datasheet describes a special lining resistant to high pressure and negative pressure. It gives no vacuum level. If your line can see vacuum, send us the lowest expected pressure so we can confirm the configuration.
Is there a 42 MPa flow meter?
Yes. 42 MPa is the highest of the five nominal classes in our datasheet. It has no outline drawing there, so confirm DN, liner and connection with us before you order.
How do I confirm the pressure designation for a PN160 magnetic flow meter?
Designations differ between unit and rating systems, and this guide gives no conversion. Please contact our sales team to confirm pressure unit conversion before you order, and send the designation you were quoted.
What does a 16 MPa flow meter cover?
16 MPa is the third of the five nominal classes. Diameter range and liner and electrode options are the same across the series. The datasheet has outline drawings for the 25 MPa class only.
What conductivity does a high pressure magnetic flow meter need?
For this model the datasheet marks 20 μS/cm. That is a specification value, not a stated minimum. Whether your medium suits the meter depends on your duty, so confirm it with our team.
Conclusion and Next Step
This guide covers a high pressure magnetic flow meter through five nominal pressure classes, its liner and electrode options, and its three oilfield uses: drilling mud, cement slurry and water injection. Confirm each against your real duty.
Send your pressure class, DN, medium, temperature and connection type. If you need a pressure designation checked, contact our sales team to confirm pressure unit conversion. We will check the fit against the datasheet options.